Call us: 1-800-366-7515

Elite Permits Logo without words

Elite Permits

Permitting Services

BUILDING PERMITS

permitting floor plan building permits
At Elite Permits, we want to make the permitting processing the easiest part of the construction process for you. We will guide you through the ever-changing building permitting process to reduce the number of rejections and expedite the issuance of your permit.
 

HEALTH PERMITS

Elite permitting Blue print

Our company has the experience to process your state health department permits for restaurants, catering, and hotels. We handle new construction, remodeled facilities, or change of ownership. We will make recommendations based upon our experience to make sure your permit gets approved. Let our experts take care of the permitting while you take care of your business.

CONTRACTOR LICENSING

Contractor licensing

While many contractors are state registered, some municipalities require registration with the local building department as well. We will review your paperwork and ensure that you have all of the required documentation, avoiding potential delays in the processing of your permits or inspections.

Consulting Services

Consulting service includes a variety of areas related to site development and building permits.

One specific area of Elite’s consulting service was created as an alternative to private provider services. Most jurisdictions require that if we do the plan review, we also do the inspections. We understand that private provider services can sometimes be cost prohibitive, therefore we also offer a portion of our services as consulting.

Our professional staff can provide a wide range of consulting activities related to the construction industry, including but not limited to:

Permit closeouts – In the course of selling a home, there may be open permits on your property that need to be finaled in order for your sale to close. Our permit specialists will evaluate and coordinate with the jurisdiction to resolve these hurdles and make it to the finish line.

Design pressure calculations – Florida Building code requires all exterior openings to meet minimum design loads. Our engineering professionals can calculate the required numbers for your project and provide the required documents for permit submittal.

Engineer letters – During the course of a building project, inspection may be inadvertently missed. With minimal destruction, our inspectors can perform an after the fact inspection to verify code and plan compliance.

Owner Inspections – Our trade inspectors will ascertain if the work has been done according to plans/specifications, county requirements, Florida Building Code and evaluate structural, electrical, mechanical, and plumbing completion.

Fire Stop inspections – Our Certified Fire Inspectors will perform penetration and joint inspections as required by NFPA 1 Section 12.3.2.

Contractor’s License Submittal/Renewal – Our permit specialists will compile and submit the necessary requirements for your county or city contractor’s license.

Department of Health License – Any establishment preparing and serving food to the public such as a restaurant, fast food service, café, sandwich shop, bar or lounge, or food service in a mall, food court, or flea market requires a Florida department of Health License. Our permit professionals will work with you to compile and submit the necessary requirements to the FDOH

icon About
Exposure represents the adjustments due the characteristics of the terrain surrounding the building.

Exposure B.For buildings with a mean roof height of less than or equal to 30 feet (9144 mm), Exposure B shall apply where the ground surface roughness, as defined by Surface Roughness B, prevails in the upwind direction for a distance of at least 1,500 feet (457 m). For buildings with a mean roof height greater than 30 feet (9144 mm), Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance of at least 2,600 feet (792 m) or 20 times the height of the building, whichever is greater.

Exposure C.Exposure C shall apply for all cases where Exposure B or D does not apply.

Exposure D.Exposure D shall apply where the ground surface roughness, as defined by Surface Roughness D, prevails in the upwind direction for a distance of at least 5,000 feet (1524 m) or 20 times the height of the building, whichever is greater. Exposure D shall also apply where the ground surface roughness immediately upwind of the site is B or C, and the site is within a distance of 600 feet (183 m) or 20 times the building height, whichever is greater, from an Exposure D condition as defined in the previous sentence.