Elite Permits

Blogs & Videos

Types of Construction

november 2021, issue 1

ELITE PERMITS

BRIEFING ON CONSTRUCTION & Some other stuff

Written by TATIANA gUSt
building construction structural

You might think at first that all buildings are built the same, but there are some small differences that make the permitting and inspection process trigger different requirements, depending on the type of construction.

Elements like occupancy classification, height of the building, and fire area per floor will be determinant factors on the type of construction. Your design professional will use these characteristics to determine the best type of construction for your project, considering the associated cost and protection of life and property in case of an emergency. 

When applying for a permit, the type of construction will be a required field that the building department needs to know when processing the permit.  For new projects, your design professional will list it on the plans, but for smaller projects you may have to make the determination based on the existing conditions. It is very important that you provide the correct information as different requirements may apply based on the construction type.

The main difference between the five different types of construction is the materials allowed to build the buildings.

In this blog we want to share with you a brief explanation of each type,  and the links to our YouTube videos where we give a more detailed explanation.

The five types of construction are:

types of construction
  • Type I – Fire-resistant (IA & IB): In Type I construction, all the materials are noncombustible, and structural elements have a minimum required fire resistance rating established by the code. This is the best type of construction, it is usually used for high-rise or large commercial buildings (ie: arenas, large movie theaters, etc.) where the potential for loss of life is really large. (YouTube video: Type I Construction (IA & IB) Explained)
  • Type II – Non-combustible (IIA & IIB): This type of construction is also where all materials are non-combustible, however, the fire resistance rating of the structural elements is lower than in type I construction. This is usually seen in commercial buildings, such as retail shopping plaza or metal storage buildings where the potential for loss of life is still significant but much less than in larger gathering venues. (YouTube video: Type II Construction (IIA & IIB) Explained)
  • Type III – Ordinary (IIIA & IIIB): This is a typical non-combustible fire rated exterior walls which have a minimum of 2 hr. fire resistance (I.e concrete block), and everything else is any material allowed by the code. We see this in low-rise buildings or restaurants where the exterior walls are block and the roof is wood trusses. Interior walls can be of any material as well. (YouTube video: Type III Construction (IIIA & IIIB) Explained)
  • Type IV – Heavy Timber: This type of construction uses structural elements which are combustible (wood) but are considered to have certain fire resistance; this is known as heavy timber construction. This construction type requires the structural wood elements to meet a minimum dimensional size requirement;  it is difficult for fire to penetrate and spread which means that buildings don’t burn easily in case of a fire, thus providing the occupants time to evacuate the building (YouTube video: Type IV Construction Explained)
  • Type V – Wood-frame (VA & VB): This type is used in smaller structures where the loss of human life is significantly reduced, since the occupants are able to leave the building fast (easier to get out of smaller buildings). This type of construction allows any material allowed by the code, even non-combustible or fire rated materials. If the building is small enough, it can always be classified as this type of construction. This is the most widely used type of construction since single family homes are usually built with a variety of materials  (YouTube video: Type V Construction (VA & VB) Explained)
trusses and structure of the building

What do A and B mean? A means protected and B means unprotected, in simpler terms, A has fire resistance rating and B has a lesser fire resistance than type A or none (it has nothing to do with sprinklers as many believe).

We hope that this provides you with a guide on what the type of construction your project is, as this will be important during the inspection process. You don’t want to be using combustible materials on a type I or II construction  It is important to know in advance so you don’t have to redo work.

At Elite Permits we can do this and so much more for you, don’t hesitate to contact us to learn more or request our services!

Elite Permits circular

Share this Post

Share on facebook
Share on twitter
Share on linkedin

Related Articles

House located in flood zone find where my house is

Find what flood zone you are in

Many times when applying for a building permit, you find out after submitting that you may be limited on what you can do based on the location and elevation of the property. These limitations are due to FEMA regulations, therefore is important for you to know your flood zone before submitting your permit.

Finding your flood zone can be confusing. In this blog, we will explain step by step how to do so.

Read More »
Florida cities

Find the municipality/jurisdiction you are in !!

In this blog, we want to share with you the first step of the permitting process. You need to find out under which building department your permit will be regulated; many times you assume it must be in “my county” but each county can have many smaller building departments within its area. This is extremely important as it will determine the requirements that apply to your project and the paperwork you have to fill out. Most jurisdiction have their own applications and they won’t accept anything other than theirs.

Read More »

What is a building permit and when do I need one?

I happen to live in Florida where we enjoy beautiful beaches and weather, however, a small price that we have to pay is to endure the occasional hurricane. I remember when I moved to Florida in May 2004, my husband told me “don’t worry about the hurricanes, I have been here for over 10 years and not even one has come through the city”. Lucky me! That year and the following year we had two major hurricanes which went through our backyard and did significant damage to our property.

Read More »
Type II Construction

Type II Construction (IIA & IIB) Explained

In our previous video we explained Type I Construction (IA & IB). Today, we describe to you, in detail, Type II. In the upcoming weeks we will also share the other types and their characteristics so you can soon distinguish them easily! Our goal is to educate you on important aspects of the construction industry.

Our goal is to educate you on important aspects of the construction industry. We have an amazing team of professionals who want to share their knowledge with you!

Read More »
Type I Construction

Type I Construction (IA & IB) Explained

In our previous video we explained the main difference between all 5 types of construction and what A and B meant. Today, we describe to you, in detail, Type I. In the upcoming weeks we will also share the other types and their characteristics so you can soon distinguish them easily!

Our goal is to educate you on important aspects of the construction industry. We have an amazing team of professionals who want to share their knowledge with you!

Read More »
Elite Permit Favorites
Social Media

Like Us On Facebook

Explore
Stay in Touch

Subscribe to our newsletter for more updates

icon About
Exposure represents the adjustments due the characteristics of the terrain surrounding the building.

Exposure B.For buildings with a mean roof height of less than or equal to 30 feet (9144 mm), Exposure B shall apply where the ground surface roughness, as defined by Surface Roughness B, prevails in the upwind direction for a distance of at least 1,500 feet (457 m). For buildings with a mean roof height greater than 30 feet (9144 mm), Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance of at least 2,600 feet (792 m) or 20 times the height of the building, whichever is greater.

Exposure C.Exposure C shall apply for all cases where Exposure B or D does not apply.

Exposure D.Exposure D shall apply where the ground surface roughness, as defined by Surface Roughness D, prevails in the upwind direction for a distance of at least 5,000 feet (1524 m) or 20 times the height of the building, whichever is greater. Exposure D shall also apply where the ground surface roughness immediately upwind of the site is B or C, and the site is within a distance of 600 feet (183 m) or 20 times the building height, whichever is greater, from an Exposure D condition as defined in the previous sentence.

 

 
Need Help with Franchising?
We are Here To Assist You

If you would like to reach us immediately:

Feel free to call us at (239) 280-0575  and we will be more than happy to answer all of your questions.