Elite Permits

Blogs & Videos

Types of Construction

november 2021, issue 1

ELITE PERMITS

BRIEFING ON CONSTRUCTION & Some other stuff

Written by TATIANA gUSt
building construction structural

You might think at first that all buildings are built the same, but there are some small differences that make the permitting and inspection process trigger different requirements, depending on the type of construction.

Elements like occupancy classification, height of the building, and fire area per floor will be determinant factors on the type of construction. Your design professional will use these characteristics to determine the best type of construction for your project, considering the associated cost and protection of life and property in case of an emergency. 

When applying for a permit, the type of construction will be a required field that the building department needs to know when processing the permit.  For new projects, your design professional will list it on the plans, but for smaller projects you may have to make the determination based on the existing conditions. It is very important that you provide the correct information as different requirements may apply based on the construction type.

The main difference between the five different types of construction is the materials allowed to build the buildings.

In this blog we want to share with you a brief explanation of each type,  and the links to our YouTube videos where we give a more detailed explanation.

The five types of construction are:

types of construction
  • Type I – Fire-resistant (IA & IB): In Type I construction, all the materials are noncombustible, and structural elements have a minimum required fire resistance rating established by the code. This is the best type of construction, it is usually used for high-rise or large commercial buildings (ie: arenas, large movie theaters, etc.) where the potential for loss of life is really large. (YouTube video: Type I Construction (IA & IB) Explained)
  • Type II – Non-combustible (IIA & IIB): This type of construction is also where all materials are non-combustible, however, the fire resistance rating of the structural elements is lower than in type I construction. This is usually seen in commercial buildings, such as retail shopping plaza or metal storage buildings where the potential for loss of life is still significant but much less than in larger gathering venues. (YouTube video: Type II Construction (IIA & IIB) Explained)
  • Type III – Ordinary (IIIA & IIIB): This is a typical non-combustible fire rated exterior walls which have a minimum of 2 hr. fire resistance (I.e concrete block), and everything else is any material allowed by the code. We see this in low-rise buildings or restaurants where the exterior walls are block and the roof is wood trusses. Interior walls can be of any material as well. (YouTube video: Type III Construction (IIIA & IIIB) Explained)
  • Type IV – Heavy Timber: This type of construction uses structural elements which are combustible (wood) but are considered to have certain fire resistance; this is known as heavy timber construction. This construction type requires the structural wood elements to meet a minimum dimensional size requirement;  it is difficult for fire to penetrate and spread which means that buildings don’t burn easily in case of a fire, thus providing the occupants time to evacuate the building (YouTube video: Type IV Construction Explained)
  • Type V – Wood-frame (VA & VB): This type is used in smaller structures where the loss of human life is significantly reduced, since the occupants are able to leave the building fast (easier to get out of smaller buildings). This type of construction allows any material allowed by the code, even non-combustible or fire rated materials. If the building is small enough, it can always be classified as this type of construction. This is the most widely used type of construction since single family homes are usually built with a variety of materials  (YouTube video: Type V Construction (VA & VB) Explained)
trusses and structure of the building

What do A and B mean? A means protected and B means unprotected, in simpler terms, A has fire resistance rating and B has a lesser fire resistance than type A or none (it has nothing to do with sprinklers as many believe).

We hope that this provides you with a guide on what the type of construction your project is, as this will be important during the inspection process. You don’t want to be using combustible materials on a type I or II construction  It is important to know in advance so you don’t have to redo work.

At Elite Permits we can do this and so much more for you, don’t hesitate to contact us to learn more or request our services!

Elite Permits circular

Share this Post

Related Articles

Plan Review

What is a Plan Review? And why does one have to be done?

What is a plan check? And why does one have to be done?
When you submit a building permit application you are telling the building department what you would like to build at your house or in your building. The person reviewing your documents are called plans examiners, and they are tasked with ensuring the proposed plans meet the current building code.

Read More »
permit time for construction

How long are permit good for?

I love this topic because people are always asking me how to extend or maintain their permit open legally, and it is actually pretty simple. The current codes tell you exactly what to do, but not all the building departments are very clear at communicating this. The main reason is they don’t want open permits for many years, as it could become a nuisance to adjacent buildings or neighbors. I have seen active permits for over 10 years, legally.

Read More »
apartments in florida

Differences between Condos, Apartments, and Townhomes.

Differences between Condos, Apartments, and Townhomes.

From our last blog the question came up about understanding townhomes. So, I decided to write a blog providing the difference between condos, apartments, and townhomes from a building code perspective.

What do all these have in common? All of these are Residential occupancy, and all of them have several living units attached to each other.

Read More »
Elite Permits building permits

Building Permit versus Permit Application

Building Permit versus Permit Application

For over 15 years, I have been working on the code enforcement side of the building process, and I love all the details that the code has to offer. For many, the code is a completely different language, and in this blog I want to make an important clarification that not many people think about it. For the non-code enforcement user, there is no significant difference between a permit and a permit application. But there is a huge difference that can be quite costly for those who are unaware.

Read More »
compliance

What building code applies to my project?

A Certificate of Occupancy and Certificate of Completion are documents issued by the building department, to the builder or owner once the construction project has been completed. These documents have different meanings, and we will review in detail what each of them represent from a building code compliance point of view.

Read More »
Elite Permit Favorites
Social Media

Like Us On Facebook

Explore
Stay in Touch

Subscribe to our newsletter for more updates

icon About
Exposure represents the adjustments due the characteristics of the terrain surrounding the building.

Exposure B.For buildings with a mean roof height of less than or equal to 30 feet (9144 mm), Exposure B shall apply where the ground surface roughness, as defined by Surface Roughness B, prevails in the upwind direction for a distance of at least 1,500 feet (457 m). For buildings with a mean roof height greater than 30 feet (9144 mm), Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance of at least 2,600 feet (792 m) or 20 times the height of the building, whichever is greater.

Exposure C.Exposure C shall apply for all cases where Exposure B or D does not apply.

Exposure D.Exposure D shall apply where the ground surface roughness, as defined by Surface Roughness D, prevails in the upwind direction for a distance of at least 5,000 feet (1524 m) or 20 times the height of the building, whichever is greater. Exposure D shall also apply where the ground surface roughness immediately upwind of the site is B or C, and the site is within a distance of 600 feet (183 m) or 20 times the building height, whichever is greater, from an Exposure D condition as defined in the previous sentence.

 

 
Need Help with Franchising?
We are Here To Assist You

If you would like to reach us immediately:

Feel free to call us at (239) 280-0575  and we will be more than happy to answer all of your questions.